Advertisement

OR signal
Set the output conditions of the OR signal.
MENU mode - [System] - [Comm] - [OR output]
Setup Item
Output mode
Output time
ENABLE signal ON range
Set the timing during measurement processing that the ENABLE signal is turned ON.
MENU mode - [System] - [Comm] - [ENABLE range] - [Range]
Setting value
Input image
Measurement
114
System Settings
Description
Sets the output conditions of the OR signal.
One-shot: The OR signal turns ON for the specified time only when the ON condition (Polarity) is
satisfied. The OR signal turns OFF when the specified time has elapsed.
Level:
The ON/OFF status is held until it next changes after the OR signal has been
output. (default value)
Sets the time that the OR signal is output as a one-shot signal.
Range: 0 to 255 ms (default value: 0 ms)
Description
Turns the ENABLE signal ON when image input is complete. This serves as a guideline
as to whether it is OK or not to move the measurement target.
TRIG
Image input
ENABLE OFF
ON
Measurement in progress
Important
When [Input image] is selected, do not input the next command until measurement is
complete even if the ENABLE signal is ON. If the next command is input, the measure-
ment currently being executed or the input command will not be executed normally.
Turns the ENABLE signal ON when measurement is complete. (default value)
TRIG
Image input
ENABLE OFF
ON
Measurement in progress
Measurement
Display
Measurement
Display
ZFX-C User's Manual