Internal Specifications

Input Specifications

RESET, DI0 to DI8, and DSA signals
Mode
Input voltage
ON current *1
ON voltage *1
OFF current *2
OFF voltage *2
ON delay
OFF delay
Internal circuit
diagram
TRIG signal
Mode
Input voltage
ON current *1
ON voltage *1
OFF current *2
OFF voltage *2
ON delay
OFF delay
Internal circuit
diagram
*1: The ON current/voltage is the value of the current/voltage that changes the status from OFF to ON. The
value of the ON voltage is the potential difference between COM IN and each input terminal.
*2: The OFF current/voltage is the value of the current/voltage that changes the status from ON to OFF. The
value of the OFF voltage is the potential difference between COM IN and each input terminal.
*3: The ON/OFF delay time for TRIG signal is different from the circuit diagram for RESET, DI0 to DI8, and DSA signals.
134

Internal Specifications

NPN
12 to 24 VDC ±10%
5 mA min.
8.8 V min.
0.5 mA max.
1.1 V max.
5 ms max.
0.7 ms max.
COMIN
Respective
terminal
NPN
12 to 24 VDC ±10%
5 mA min.
8.8 V min.
0.5 mA max.
0.8 V max.
0.1 ms max.
0.1 ms max.
COMIN
Respective
terminal
PNP
12 to 24 VDC ±10%
5 mA min.
8.8 V min.
0.5 mA max.
1.1 V max.
5 ms max.
0.7 ms max.
Respective
terminal
COMIN
PNP
12 to 24 VDC ±10%
5 mA min.
8.8 V min.
0.5 mA max.
0.8 V max.
0.1 ms max.
0.1 ms max.
Respective
terminal
COMIN