Signal Operation in terms of Measurement

Trigger Input
OFF
TRIG
ON
OFF
ENABLE
ON
Close
Shutter open/close
Open
OFF
STGOUT0,1
ON
T1:
Trigger input time
T2:
ENABLE output
response time
T3:
Measurement time
T4:
Trigger delay time
T5:
Shutter time
T6:
Strobe delay time
T7:
Strobe pulse width
Explanation of operation
(1) The STGOUT signal is used to output the strobe firing trigger to the strobe device connected to the
Controller. After the shutter opens, the STGOUT signal is output after the STGOUT delay time (T6) has
elapsed, and the strobe fires. The ON/OFF polarity of the STGOUT signal can be changed.
146
Timing Charts
T2
Set to ON for at least 0.5 ms.
This is the time after the trigger is input until the ENABLE signal turns ON. 0.5 ms or less
This time is "image input" + "measurement". This time can be changed to only "image
input" or "image input" + "measurement" + "display".
This is the time after trigger input until the camera's shutter is opened (max. 65.535 ms).
This is the time that the image is captured (max. 2 ms).
This time can be changed by setting the shutter speed.
This is the time after trigger input until the Controller outputs the STGOUT signal (max.
65.535 ms).
This is the strobe trigger output time (max. 65.535 ms).
ZFX-C User's Manual