Omron ZFX-C10 User Manual page 54

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Region settings
This function sets the region to be registered as the model and the region to search for the model.
MENU mode - [Setup] - [Item] - [Region]
Item
Register model
Reference model
Search region
Threshold
This function sets the judgment conditions.
MENU mode - [Setup] - [Item] - [Limits]
Setup Item
Correlation
Position XY
Solid color rate
Angle
Image adjustment (if necessary)
The following items can be changed and set to the image of the measurement target.
MENU mode - [Setup] - [Item] - [Img Adj]
Item
Color filter
Filtering
BGS level
52
Setting Measurement Items
Description
This function registers the image pattern to find as the model.
Setting the Region p.178
The image that is registered as the model can be referenced.
Sets the region in which to search for the model.
Description
Sets the range of the correlation to be judged as OK.
Range: 0 to 100
Sets the range of movement in the X- and Y- axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999
(When calibration is OFF, the range of movement for positions X and Y are 0 to 640 and 0
to 480, respectively.)
Sets the range of solid color to be judged as OK.
Range: 0 to 100
Sets the range of rotation angle to be judged as OK.
Range: -180 to 180
+/- direction of angle p.47
Description
For details, see "Image Adjustment". p.80
ZFX-C User's Manual