Serial Communications Instructions
Auxiliary Area Flags for Serial Communication Board's Ports
Port
Name
Port 1
Reception Completed
Flag
Reception Overflow
Flag
Reception Counter
Overrun Error Flag
Port 2
Reception Completed
Flag
Reception Overflow
Flag
Reception Counter
Overrun Error Flag
Ports 1
Inner Board Service
and 2
Disabled Flag
Address
Contents
A35606
ON when no-protocol reception is com-
pleted.
Number of Receive Bytes Specified:
The flag will turn ON when the specified
number of bytes has been received.
End Code Specified: The flag will turn
ON when the end code is received or
when 256 bytes have been received.
A35607
ON when more that the expected num-
ber of receive bytes has been received
in no-protocol mode.
Number of Receive Bytes Specified:
The flag will turn ON when more data is
received after reception was completed
but before the received data was not
read from the buffer with RXD(235).
End Code Specified: The flag will turn
ON when 257 or more bytes of data are
received without an end code.
A357
Counts in hexadecimal the number of
bytes received in no-protocol mode (0 to
256 decimal).
CIO 1908
ON when 260 or more bytes of data are
bit 04
received in the buffer before RXD(235)
is executed.
A35614
ON when no-protocol reception is com-
pleted.
Number of Receive Bytes Specified:
The flag will turn ON when the specified
number of bytes has been received.
End Code Specified: The flag will turn
ON when the end code is received or
when 256 bytes have been received.
A35615
ON when more that the expected num-
ber of receive bytes has been received
in no-protocol mode.
Number of Receive Bytes Specified:
The flag will turn ON when more data is
received after reception was completed
but before the received data was not
read from the buffer with RXD(235).
End Code Specified: The flag will turn
ON when 257 or more bytes of data are
received without an end code.
A358
Counts in hexadecimal the number of
bytes received in no-protocol mode (0 to
256 decimal).
CIO 1918
ON when 260 or more bytes of data are
bit 04
received in the buffer before RXD(235)
is executed.
A42404
ON when RXD(235) is executed for a
Serial Communications Board that does
not support no-protocol mode (a Board
without a version number).
Section 3-24
1001