Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Reference Manual page 1256

Programmable controllers
Hide thumbs Also See for SYSMAC CJ - REFERENCE MANUAL 08-2008:
Table of Contents

Advertisement

Block Programming Instructions
Operand Specifications
Description
1216
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
Task Flags
Condition Flags
Clock Pulses
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
LOOP(809) designates the beginning of the loop program. LEND(810) or
LEND(810) NOT specifies the end of the loop. When LEND(810) or
LEND(810) NOT is reached, program execution will loop back to the next pre-
vious LOOP(809) until the operand bit for LEND(810) or LEND(810) NOT
turns ON or OFF (respectively) or until the execution condition for LEND(810)
turns ON.
CIO 000000 to CIO 614315
W00000 to W51115
H00000 to H51115
A00000 to A44715
A44800 to A95915
T0000 to T4095
C0000 to C4095
TK0000 to TK0031
ER, CY, >, =, <, N, OF, UF, >=, <>, <=, ON,OFF, AER
0.02 s, 0.1 s, 0.2 s, 1 s, 1 min
---
---
---
---
---
---
---
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Section 3-32