Text String Processing Instructions
Variations
Applicable Program Areas
Operands
INS$(657)
S1
S2
S3
D
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation
Immediate Refreshing Specification
Block program areas
OK
S1: Base Text String
S2: Inserted Text String
S2 + maximum 2,047 words
S3: Beginning Position (0000 to 0FFF hex or &0 to &4095)
Note
1. The data from S1 to S1 + the maximum 2,047 words, from S2 to S2 + the
maximum 2,047 words, and from D to D + the maximum 2,047 words must
be in the same area.
2. The data from S2 to S2 + the maximum 2,047 words and from D to D + the
maximum 2,047 words cannot overlap. The data from S1 to S1 + the max-
imum 2,047 words and from D to D + the maximum 2,047 words can over-
lap. The data from S1 to S1 + the maximum 2,047 words and from S2 to
S2 + the maximum 2,047 words can also overlap.
S1: Base text string first word
S2: Inserted text string first word
S3: Beginning position
D: First destination word
Step program areas
OK
15
S1
Text string data: 4,095 characters max. + NUL
to
S1 + maximum 2,047 words
15
S2
Text string data: 4,095 characters max. + NUL
to
15
D
Text string data: 4,095 characters max. + NUL
to
D + maximum 2,047 words
Section 3-33
INS$(657)
@INS$(657)
Not supported
Not supported
Subroutines
Interrupt tasks
OK
OK
0
0
0
1247