Table Data Processing Instructions
Operand Specifications
728
C+1
The following table shows the possible values of C.
C+1
Data type
0000
Unsigned binary
4000
Unsigned binary
8000
Signed binary
C000
Signed binary
R1: First word in range
R1 specifies the first word in the search range. The words from R1 to R1+(C–
1) are searched for the maximum value. (C is the number of words specified in
C.)
Note R1 and R1+(C–1) must be in the same data area.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank E00000 to E32766
EM Area with bank
15
C
Number of words in range
15
14
13
00 0000
0000
Output selection
0: Does not output address to IR00.
1: Outputs address to IR00.
Data type
0: Unsigned binary data
1: Signed binary data
Index Register output
No
Yes
No
Yes
15
Search range
R1
to
---
R1+(C–1)
C
CIO 0000 to
CIO 6142
W000 to W510
H000 to H510
A000 to A958
T0000 to T4094
C0000 to C4094
D00000 to D32766
En_00000 to
En_32766
(n = 0 to C)
Section 3-17
0
0
0000
0
0
R1
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A959
A448 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
D