For Step 3 to Step 10, collect data according to the prompts.
After the acquisition is completed, carry out calibration calculation:
The camera calibration results are as follows:
If the calibration fails, click the "Recalibrate" button and repeat the steps above to recalibrate.
After successful calibration, click Next to enter the white balance calibration.
4.2.2. White Balance Calibration
To ensure that accurate texture data is obtained, it is recommended that a white balance
calibration be performed each time the ambient brightness changes. White balance calibration
environment:
Use light box (power: 60W; input voltage: 110V-240V) for dark environment. White
illumination environment suggested. Yellow light might cause large color deviation.
No direct strong light
Even illumination