STAR Radio Protocol Timeout

This parameter sets the valid wait time before transmission between the handheld
reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of read-
ers in the same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 =
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See following table for some examples of how to set this
feature.
Table 24 STAR Radio Protocol Timeout Examples
STEP
1
Desired Setting
2
Pad with leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
Scan two characters from
5
Appendix D
5
Scan ENTER/EXIT PROGRAMMING MODE
05, 25 = 25, etc
Mode.
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
ACTION
EXAMPLES
2 Seconds
5 Seconds
02
05
'0' and '2'
'0' and '5'
RF FEATURES
, that represent the
Appendix D
10 Seconds
25 Seconds
10
25
'1' and '0'
'2' and '5'
PRODUCT REFERENCE GUIDE