ENTER/EXIT PROGRAMMING MODE

2D Maximum Decoding Time

This feature specifies the maximum amount of time the software will spend attempting
to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
$CDETM0A
2D Maximum Decoding Time = 200 msec
$CDETM23
2D Maximum Decoding Time = 500 msec
$CDETM64
2D Maximum Decoding Time = 2 Seconds
$CDETMFF
198
QUICKSCAN™ 2500
2D Maximum Decoding Time = 100 msec
$CDETM14
2D Maximum Decoding Time = 350 msec
$CDETM32
2D Maximum Decoding Time = 1 Second
$CDETMC8
2D Maximum Decoding Time = 2.55 Seconds