ENTER/EXIT PROGRAMMING MODE
Data Bits
This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit
ASCII protocol for sending and receiving data.
$CR2DA00
8 Data Bits
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission
of one character and prepares the receiving device for the next character in the serial
data stream. The number of stop bits selected (one or two) depends on the number the
receiving terminal is programmed to accommodate. Set the number of stop bits to
match host device requirements..
$CR2ST00
2 Stop Bits
32
QUICKSCAN™ 2500
NOTE: Handheld and base station models support the 8-bit ASCII protocol.
The 7-bit ASCII protocol support is subject to specific firmware release.
If the setting is not supported, the reader will emit three short beeps upon
scanning the label.
RS-232 INTERFACE
7 Data Bits
$CR2DA01
1 Stop Bit
$CR2ST01