When operation is OK, the SYS LED flashes green, regularly, and once per two second in the display on
the front panel. The system is in normal mode. Other operating states are signalled differently. This is
described in chapter

System error displays

Whenever the system detects an error, it displays the corresponding error code in the LED display field
of the front panel (providing the communication server is still powered and the display is working).
In the event of sporadic errors check the installation for earth loops.

Terminals

Table
6.15:Malfunctions on the terminal side
Error description
Digital system phones on the DSI bus display
Not Configured along with the node
number, the slot number and the port
number.
System phones do not obtain any dial tone
when seizing a line; display reads Not
available.
Terminals with configurable dialling method
experience sporadic malfunctions whenever
control key is pressed.
Analogue terminals do not obtain a dial tone
when off-hook.

Operating state of the Mitel DECT radio units

Each radio unit is equipped with 3 LEDs. The operating state the radio units is indi-cated by different
colours and flashing sequences in cycles of 1 s, specifically by one of the two outer LEDs on the SB-4+
and by both outer LEDs on the SB-8 / SB-8ANT (separately for each DSI bus). Each character (G, R or
-) corresponds to 1/8 of a second.
Example:
During the synchronization phase GGGGRRRR the LED flashes periodically. 1/2 second green, 1/2
second red.
Operating
modes.
Error cause / error handling
No terminal has yet been created on the
connected port or an incorrect terminal
selection digit (TSD) has been allocated to
the terminal:
Check system and terminal configura-
tion
Check installation and connecting cable
Replace phone or interface card.
System earth must not be connected on
terminals configured for MFV/DTMF (double
signalling on Flash/earth key).
No terminal has been created on the
connected port or the terminal created has
not been allocated to a user.
Create a terminal and allocate a user
Check installation or connecting cable