Installation rules
•
If a Mitel DECT radio unit is used, do not connect any other system phone to the same DSI bus.
•
Do not use any terminating resistors at the bus extremity.
•
Avoid using different cable cross-sections on the same bus
•
Use the supplied cables for connecting the system phones
•
Cabling of AD2 terminals is restricted to pairs of a separate dedicated cable(s).
Terminals
The following system terminals can be operated on the DSI-AD2 bus:
•
MiVoice 5300 series system phones
•
Mitel DECT radio units
The system phones on an DSI-AD2 bus are addressed via a single-digit terminal selection digit (TSD).
Example:
The address of a system phone with TSD 2 on DSI interface 3.5 is 3.5-2.
BRI-S terminal interfaces
: Some of the interfaces can be configured on BRI-T using the wiring adapters (see
NOTE
adapter).
Connection
Table