– The electromagnetic interference (EMI) integrity and cooling of the node are protected by having all
bays and PCI and PCIe slots covered or occupied. When installing a drive, PCI, or PCIe adapter, save
the EMC shield and filler panel from the bay or PCI or PCIe adapter slot cover in the event that you later
remove the device.
– For a complete list of supported optional devices for the node, see
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sd530v3/7dd3/downloads/driver-
to see the latest firmware and driver updates for your server.
list
• Go to
"Update the firmware" on page 185
Procedure
Step 1.
Remove the E3.S drive cage cover.
a.
Loosen the thumbscrew on the drive cage cover.
b.
Pull the drive cage cover out of the node.
Figure 53. E3.S drive cage cover removal
Step 2.
If the drive bay contains a filler, pull the release lever on the filler and slide it out of the bay.
Step 3.
Install the E3.S hot-swap drive.
a.
Make sure that the drive handle is in the open position. Then, align the drive with the guide
rails in the bay and gently slide the drive into the bay until it stops.
b.
Rotate the drive handle to the fully closed position until the handle latch clicks.