Figure 5-4 Auto Update Screen Change - Zhone 100 User Manual

Zhone netpath 100 network-accessory: install guide
Table of Contents

Advertisement

5 Diagnostics
5-6
4. Initiating certain test options, when management access is via the T1 link, will
terminate management.These tests will be blocked and an Error Message
displayed on the screen. Examples of this are "BERT to Netw" and "Test Pkts to
Netw" where the DLCI selection matches the management DLCI of this unit.
High Speed Interface Status -
DTR: State of DTR lead, when Power is being detected from the DTE.
States are: ON, OFF or (blank) if Power OFF.
RTS: State of RTS lead, when Power is being detected from the DTE.
States are: ON, OFF or (blank) if Power OFF.
Power: ON or OFF based on sensing voltage on Tx data lead(s) from the DTE.
Interface: Interface adapter cable currently installed.
Types are: ITU-V35, EIA-530, EIA-530-A, ITU-X21-NS or
(blank) if none.
Commands:
ResetTest [RT] - Resets BERT or PVC result counters without disrupting the test
operation and refreshes all dynamic information contained on the screen.
InjectErr [IE secs] - Injects a single bit error into the BERT stream. When issued
without the "secs," a single bit error will be injected at execution of this command.
When issued with a "secs" value between 1 - 255, a single bit error will be injected
once a second for the number of "secs" entered (user can issue other commands while
this takes place in background).
RebootExt [RE secs] - Causes the optional external Power Control Unit to interrupt
AC Power to the DTE device. When issued without the "secs," power will be in-
terrupted for five seconds at execution of this command. When issued with a
"secs" value between 1 - 30, power will remain off for the number of seconds en-
tered.
Help [?] - Advances to "Help" for PVC Performance Configuration screen.
Close [X] - Returns to System View screen.
AutoUpdate [AU] - Provides automatic screen update and refresh (every five sec-
onds) of all status and Test (when active) results. No changes can be made while in this
mode, and the bottom lines on the screen are replaced as shown in Figure 5-4. AutoUp-
date is exited by pressing ENTER.
--->
Screen updates every 5 seconds
--->
Press Enter for Command Prompt

Figure 5-4 Auto Update Screen Change

NetPath 100 User's Manual - Installation Guide
<---
<---
980-001-0210G
June 1999

Advertisement

Table of Contents
loading

Table of Contents