Csu / Dte Configuration; Figure 4-8 Csu / Dte Configuration Screen - Zhone 100 User Manual

Zhone netpath 100 network-accessory: install guide
Table of Contents

Advertisement

4 Operation
CSU / DTE
Configuration

**************************** CSU / DTE Configuration ***************************

Name: F@43802
Data Rate: 1344 kbs
Number of DS0's [N=]: 24
Starting DS0 [S=]: 1
DS0 Pattern [P=]
>>1) Contiguous<<
2) Alternate
Link Err Thres [L=#]: Disabled
X to Disable or 1 thru 895 seconds
Help[?]
>
4-16
The CSU / DTE Configuration screen allows you to view and alter parameters for the
CSU and DTE interface operations.
The CSU / DTE Configuration screen is shown in Figure 4-8.
T1 ID [I=]: NONAME
1 thru 24
DS0 Format [F=]
>>1) Nx56 kbs<<
2) Nx64 kbs
Save[SA]
Cancel[X]

Figure 4-8 CSU / DTE Configuration Screen

1. T1 ID - Enter an ID for this T1.
2. Data Rate - Displays the data rate which results from the settings for "Number of
DS0's" and "DS0 Format."
3. Number of DS0's, Starting DS0, and DS0 Pattern - Select which DS0s will be
used to form the data payload.
4. DS0 Format - Select data rate for all DS0s in the payload.
5. Build Out - Selects the Line Build-Out value for the T1 line connection.
6. Ones Dens - Selects the Ones Density format to be used.
7. T1 Framing - Selects T1 Framing format to be used.
NOTE: ANSI or AT&T are ESF format, SF includes D4.
8. DTE TxD Clk - Configure the DTE to clock in the Tx data based on either the
DCE (NetPath) supplied clock, or the DTE (cable loop or router) supplied clock.
9. Link Err Thres - Disables or sets the threshold of Rx Errored Seconds plus
Unavailable Seconds which when reached or exceeded will cause an alarm to be
declared.
NetPath 100 User's Manual - Installation Guide
Build Out [B=]
T1 Framing [T=]
>>1) T1-0<<
>>1) ANSI<<
2) T1-7
2) AT&T
3) T1-15
3) SF
4) T1-22
Ones Dens [D=]
DTE TxD Clk [C=]
>>1) B8ZS<<
>>1) DCE<<
2) AMI
2) DTE
980-001-0210G
June 1999