Table 1-15 Test/Bkp (Dsx - Zhone 100 User Manual

Zhone netpath 100 network-accessory: install guide
Table of Contents

Advertisement

Test/BKP
(DSX)
Display
Mgmt Line Netw
Mgmt Pyld Netw
Mgmt QRSS Netw
Mgmt Alt1 Netw
Mgmt 2047 Netw
Mgmt Zero Netw
Mgmt Loop Cpe
Mgmt Send Lp Up
Mgmt Send Lp Dn
Netw Set Line
Netw Set Payld
Dsx Loop Netw
Dsx 2047 Netw
Dsx Zero Netw
Dsx Line Dsx
Dsx Pyld Dsx
Dsx QRSS Dsx
Dsx 2047 Dsx
980-001-0210G
June 1999
Test/BKP shows the highest priority CSU or DSX related test or Backup (ISDN) con-
dition currently detected. This is displayed on the CSU/DSX Statistics Summary
screen when in DSX Mode.

Table 1-15 Test/BKP (DSX)

Operator initiated Full T1 Line loopback in place at Network Port toward Network
Circuit.
Operator initiated Full T1 Payload loopback in place toward Network Circuit.
Operator initiated QRSS pattern BERT is being sent toward the Network Circuit.
Operator initiated Alternating Ones pattern BERT is being sent toward the Network
Circuit.
Operator initiated 2047 pattern BERT is being sent toward the Network Circuit.
Operator initiated All Zeros pattern BERT is being sent toward the Network Circuit.
Operator initiated Full T1 Line Loopback applied within the unit's framer toward the
CPE port(s): User Port (also DSX Port and Drop Port if DSX/Drop Adapter installed.)
Operator initiated T1 Line Loop Up code sent toward the Network.
Operator initiated T1 Line Loop Down code sent toward the Network.
Externally initiated (Network sent code) Full T1 Line loopback in place at Network
Port toward Network Circuit.
Externally initiated (Network sent code) Full T1 Payload loopback in place toward
Network Circuit.
Operator initiated Loopback is in place at the DSX Port (for DS0s assigned to DSX
Port @ Nx64K) toward the Network Circuit.
Operator initiated 2047 pattern BERT is being sent toward the Network Circuit (for
DS0s assigned to DSX Port @ Nx56K.)
Operator initiated All Zeros pattern BERT is being sent toward the Network Circuit
(for DS0s assigned to DSX Port @ Nx56K.)
Operator initiated Full T1 Line Loopback in place toward the DSX Circuit.
Operator initiated Full T1 Payload loopback in place toward the DSX Circuit.
Operator initiated Full T1 QRSS pattern BERT is being sent toward the DSX Circuit.
Operator initiated 2047 pattern BERT is being sent toward the DSX Circuit.
NetPath 100 User's Manual - Installation Guide
Description
Appendix
A-17