Zhone 100 User Manual page 160

Zhone netpath 100 network-accessory: install guide
Table of Contents

Advertisement

Appendix
Display
Dsx Pyld Dsx
Dsx QRSS Dsx
Dsx 2047 Dsx
Drop Loop Netw
Drop 2047 Netw
Drop Zero Netw
Drop Loop Drop
Drop 2047 Drop
Netw Set User
Netw Set Drop
Lcl Lp Set User
Lcl Lp Set Drop
A-16
Table 1-14 Test/BKP (CSU)
Operator initiated Full T1 Payload loopback in place toward the DSX Circuit.
Operator initiated Full T1 QRSS pattern BERT is being sent toward the DSX Circuit.
Operator initiated 2047 pattern BERT is being sent toward the DSX Circuit.
Operator initiated Loopback is in place at the Drop Port toward the Network Circuit.
Operator initiated 2047 pattern BERT is being sent toward the Network Circuit (for
DS0s assigned to Drop Port).
Operator initiated All Zeros pattern BERT is being sent toward the Network Circuit
(for DS0s assigned to Drop Port).
Operator initiated Loopback is in place at the Drop Port toward the Drop Circuit.
Operator initiated 2047 pattern BERT is being sent toward the Drop Circuit.
Loopback is in place at the User Port toward the Network Circuit, in response to a V.54
LoopUp code from the Network (only if DS0s are assigned to the User Port.)
Loopback is in place at the Drop Port toward the Network Circuit, in response to a V.54
LoopUp code from the Network (only if DS0s are assigned to the Drop Port.)
Loopback is in place at the User Port toward the User Circuit, in response to an LL
(Local Loopback) signal at the User Port interface (only if DS0s are assigned to the
User Port.)
Loopback is in place at the Drop Port toward the Drop Circuit, in response to an LL
(Local Loopback) signal at the Drop Port interface (only if DS0s are assigned to the
Drop Port.)
NetPath 100 User's Manual - Installation Guide
Description
980-001-0210G
June 1999