Adapter Cable; Table 3-5 Eia-530 Interface Adapter Cable (Cbc=2) - Zhone 100 User Manual

Zhone netpath 100 network-accessory: install guide
Table of Contents

Advertisement

3 Installation
EIA-530 Adapter
Cable

Table 3-5 EIA-530 Interface Adapter Cable (CBC=2)

DB-25F
DB-44M
Pin
Pin
1
16
2
17
3
18
4
19
5
20
6
21
7
22
Sig. Gnd.
8
23
9
42
10
38
11
44
12
40
13
35
Notes: *CBC = Cable Code pin.
(s) = single ended.
Twisted Pair cable conductors for: TD-A & B, RD-A & B, RTS-A & B, CTS-A & B, DSR-A & B,
Shielded cable is recommended.
3-10
Use CRC cable assembly # 135-002-0400, or per pinout shown in Table 3-5.
Signal
Direction
Shield
N/A
TD-A
Input
RD-A
Output
RTS-A
Input
CTS-A
Output
DSR-A
Output
N/A
DCD-A
Output
RC-B
Output
DCD-B
Output
TCE-B
Input
TC-B
Output
CTS-B
Output
DCD-A & B, DTR-A & B, TC-A & B, RC-A & B and TCE-A & B.
NetPath 100 User's Manual - Installation Guide
DB-25F
DB-44M
Pin
Pin
14
32
15
25
16
33
17
27
18
19
34
20
24
21
22
36
23
39
24
29
25
26 to 22
CBC-A*
28
CBC-B*
30 to 22
CBC-C*
Signal
Direction
TD-B
Input
TC-A
Output
RD-B
Output
RC-A
Output
RTS-B
Input
DTR-A
Input
DSR-B
Output
DTR-B
Input
TCE-A
Input
Cable Code - A
Cable Code - B
Cable Code - C
980-001-0210G
June 1999

Advertisement