Configuring the Overall System

The following section describes how to configure the System menu options:
T

Configuring General System Options

Select General from the System menu to configure the general system
configuration options (see
Table 3-1.
7123-A2-GB20-00
Configuring General System Options
Main Menu
Configuration
General System Options
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether or not loopback and pattern tests have a duration after which they
are terminated automatically. This setting does not effect DTE-commanded tests or the
LMI Packet Capture Utility feature.
Enable – All Loopback and Pattern tests have a timeout.
Disable – Loopback and pattern tests must be manually terminated.
Test Duration (min)
Possible Settings: 1 – 120
Default Setting: 10
Specifies the maximum duration of user-initiated tests.
Display Conditions – This option only appears when Test Timeout is set to Enable.
1 – 120 – Sets the Test Timeout period in minutes (inclusive).
Primary Clock Source
Possible Settings: Net1, Internal
Default Setting: Net1
Allows you to select the primary clock source for the unit. The source selected provides all
of the timing within the DSU/CSU and the clocks for all of the external interfaces.
Net1 – The primary clock is derived from the Network1 interface.
Internal – The primary clock is the internal clock.
September 2001
Table 3-1, General System
System
General
3. Configuration
Options).
3-9