Alarms
Table 6-1, Alarm
SNMP trap for a physical interface. These alarm conditions also generate Health
and Status messages seen on the System and Test Status screen.
Table 6-1.
7123-A2-GB20-00
Conditions, describes the alarm conditions that will generate an
Main Menu
Status
Alarm Conditions (1 of 3)
Alarm Condition
What It Indicates
AIS at Network 1
An Alarm Indication Signal
(AIS) is being received by
the interface. AIS is an
unframed, all ones signal.
CTS down to
The CTS control lead on the
Port-1 Device
device's interface is off.
DTR Down from
The DTR control lead on
Port-1 Device
the device connected to the
specified port is off. This
message applies to data
ports that act as DCEs.
EER at Network 1
The error rate of the
received network signal
exceeds the currently
configured threshold. This
condition only occurs if the
network interface is
configured for ESF framing.
This condition clears when
the error rate falls below the
threshold value, which may
take up to 15 minutes.
Ethernet Link Down
The communication link for
the Ethernet port is down
and the Interface Status for
the port is enabled.
September 2001
System and Test Status
What To Do
For the network interface, report
the problem to your T1 service
provider.
Check DTR and RTS from Port-1.
T
T
Examine the attached DTE and
cable connected to the system's
port.
T
T
T
T
Check the LAN connected to the
Ethernet port.
6. Troubleshooting
Verify that the port is enabled.
Check DTR from the user data
port.
Check that the port cable is
securely attached at both ends.
Check the status of the
attached equipment.
Verify that the network cable is
securely attached at the
network interface.
Contact your network provider.