Trigger Control - JAI GO-5000M-USB-UV User Manual

Cmos digital progressive scan monochrome uv camera with usb interface
Hide thumbs Also See for GO-5000M-USB-UV:
Table of Contents

Advertisement

GO-5000M-USB-UV User Manual (Ver. 1.1)

Trigger Control

The following 5 types of Trigger Control are available by the combination of Trigger Selector, Trigger
Mode, Exposure Mode and Trigger Option.
Camera Settings
Trigger
Trigger
Exposure
Selector
Mode
Off
Off
Off
Timed
Frame
Start
On
Timed
On
Timed
Trigger
On
Width
Trigger Selector
Selects the trigger operation. On this camera, the following trigger operation can be selected as the
trigger.
Trigger Selector Item
Frame Start
Acquisition Start
Acquisition End
Acquisition Transfer Start
Each trigger has the following setting parameters, and those parameters are configured on each
trigger selector item.
Setting parameters: Trigger Mode, Trigger Software, Trigger Source, Trigger Activation
Trigger Mode
Select either free-running operation or external trigger operation.
OFF: Free-running operation
l
ON: External trigger operation
l
JAI Custom Trigger
Trigger
Mode
Option
Off
Continuous Trigger
Off
Continuous Trigger
Off
EPS Trigger
RCT
RCT Trigger
Off
PWC Trigger
Frame Start Trigger operation
Acquisition Start Trigger operation
Acquisition End Trigger operation
Transfer Trigger operation (for delayed readout)
Mode Name
Free-running operation with the maximum
exposure time per the frame rate
Free-running operation with a user-set
exposure time.
Externally triggered operation with a user-set
exposure time
Externally triggered operation for RCT
Externally triggered operation with a pulse
width exposure time
- 57 -
Description
Description
Main Functions

Advertisement

Table of Contents
loading

Table of Contents