GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
ALC Channel Area

Trigger Control

The following 5 types of Trigger Control are available by the combination of Trigger Selector, Trigger
Mode, Exposure Mode and Trigger Option.
Camera Settings
Trigger
Trigger
Exposure
Selector
Mode
Off
Off
Off
Timed
Frame
Start
On
Timed
On
Timed
Trigger
On
Width
JAI Custom Trigger
Trigger
Mode
Option
Off
Continuous Trigger
Off
Continuous Trigger
Off
EPS Trigger
RCT
RCT Trigger
Off
PWC Trigger
Mode Name
Free-running operation with the maximum
exposure time per the frame rate
Free-running operation with a user-set
exposure time.
Externally triggered operation with a user-set
exposure time
Externally triggered operation for RCT
Externally triggered operation with a pulse
width exposure time