Programmable Wireless Input 4 - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

DAAB AUTOMATIC CONTROL UNIT EP104

Programmable wireless input 4

No.
Name
r001
Readout of received wireless input
0
No wireless reception
1
Wireless input 1 is receiving a wireless signal
2
Wireless input 2 is receiving a wireless signal
3
Wireless input 3 is receiving a wireless signal
4
Wireless input 4 is receiving a wireless signal
r460
Control function
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
r462
Half operation
1
Motor 1
2
Motor 2
3
Motor 1 and Motor 2
r463
Limited opening
0
Disabled
1
Time opening according to set time in channel C412/C414 or number of degrees in L116/L126 if
encoder is used.
r470
Disable operation at wireless input 4.
0
Disabled, normal operation. (Programmable input has no function for wireless input 4)
1
Operate only if there is a signal at programmable input 1
2
Operate only if there is a signal at programmable input 2
3
Operate only if there is a signal at programmable input 3
4
Operate only if there is a signal at programmable input 4
5
Operate only if there is a signal at programmable input 5
6
Operate only if there is a signal at programmable input 6
r480
Park
0
Disabled
1
Park without automatic closing Reset by another control signal
r490
Interlock opening
0
Disabled
1
Sends a normal open signal to the remote door
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
0 - 4
0
0 - 5
0
1 - 3
3
0 - 1
0
0 - 6
0
0 - 1
0
0 - 1
0
page
34
77

Advertisement

Table of Contents
loading

Table of Contents