Technical Specification - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

Technical specification

Dimensions (WxHxD)
Power supply
Power supply
Permitted voltage variation
Frequency
Motor in 3-phase operation
3x400 V
Motor in 3-phase operation
3x230 V
Motor
in
single-phase
operation
Fuses
Power consumption
Operating mode
Temperature range
Safety edge
Safety circuit
Internal motor protection
Load guard
Digital inputs
Supply voltage for photocell 24 VDC max. 50 mA.
External supply
Communication
Protection class
10
190x224x60 mm.
3-phase or single-phase.
3x400V+N+PE, 3x230V+PE, 1x230V+N+PE, 3x400V+PE (requires an external transformer)
±10%
50 Hz.
3-phase asynchronous motor 0.18-1.5 kW.
3-phase asynchronous motor 0.18-0.75kW.
Single-phase motor with capacitor 0.18-0.37 kW.
External fuse max. T10A.
Automatic control unit 22 VA + electric motors.
Intermittent operation 50% / maximum period of operation 4 minutes
0 to 45 °C.
2 closing inputs S.E1 and S.E2 for a safety edge while closing.
1 opening input S.E3 for a safety edge while opening.
Variable impedance 1.0-9.9 kΩ, power capability at least ½ W.
Max. impedance 3 Ω in the stop circuit.
Cable length 0.75 mm2 max. 60 m. Cable length 1.5 mm2 max. 120 m.
One 0-50 V analogue input to measure the voltage after the stop circuit.
Setting range 0.5-6 A.
Setting range 0.05-1.99 kW.
9
Logical 0 0-8 VDC.
Logical 1 12-30 VDC.
Input current 5 mA at 24 VDC.
Cable length max. 200 m
24 VDC max. 300 .
RS-485 between two EP104 units. Cable length max. 1000m.
The PCB is designed for an enclosure rating of at least IP54.
DAAB AUTOMATIC CONTROL UNIT EP104