Functions using add-in cards

Add-in cards can be installed in the EP104 for access to extra functions. The add-in cards are DB401 for programmable
outputs, DB402 for a vehicle detector, DB403 (DBR1 system) for four programmable wireless inputs, DB404 (FAAC SLH
system) for one programmable input and DB406 for motor control using a frequency converter.
Follow the instruction manual supplied with the add-in card when installing the card in the EP104.

• Programmable outputs, o channels

You can use the DB401 add-in card to access four programmable outputs in the EP104.

Function of programmable outputs 1 - 3

The instructions are identical for these three programmable outputs, apart from the channel number – output 1 has channel
number o1nn, output 2 has channel number o2nn, etc. The settings below are for output 1.
Activate programmable output 1 by setting o100 to the desired function. A value of 0 means that the output is disabled
(open) regardless of the settings of other channels.
If you set the value to 1, the output can be used as a traffic light signal based on the position indication. Movement and
warning time signals are also available with this setting. The value 2 is for presence detection in the vehicle loop, the value
3 is for motor locks, and the value four turns the output into an alarm output.
Channel o110 Open position
Set to 1 for a constant signal in the open position.
Channel o111 Mid position
Set to 1 for a constant signal in the mid position.
Channel o112 Closed position
Set to 1 for a constant signal in the closed position.
Example for a green light: o110 = 1, o111 = 0, o112 = 0.
Example for a red light: o110 = 0, o111 = 1, o112 = 1.
Channel o113 Movement
Use this channel to specify the function during movement. The function will be active as soon as the door starts moving.
See the channel reference for the available options. Only output 4 is able to send a flashing signal.
Channel o120 Warning time before start The time can be set to 0.00 – 9.59 minutes. 0.00 means the function is disabled
and the time for the function is defined in o121.
Channel o121 Warning function in combination with channel o120
Set the value to 1 for a constant signal before an opening movement, 2 for a constant signal before a close signal, parking
and automatic closing, 3 for a signal within all control signals.
Channel o130 Delay for alarms specified in o131 and o132. The alarm is delayed by the set time of 0.00 – 9.59 minutes.
The factory setting is 0.00.
Channel o131-o139 Alarms for various conditions
If it is set to 1 it gives a signal when the condition, according to the channel specification, has been fulfilled for longer than
the time set in o130.
Channel o191 Function when LOOP2, LOOP2 or PHOTO are activated:
Used to set the presence detection required from the vehicle loop. See the channel reference for the available options.
Select the output to be normally open or normally closed by setting channel o183 to:
The value 1 is for normally open (NO) and the value 2 is for normally closed (NC).

Function of programmable output 4

In principle, programmable output 4 is the same as outputs 1, 2 and 3, except that it is a triac output. The settings are all
the same as for outputs 1, 2 and 3, except that output 4 also supports flashing signals. See the channel reference for the
channel settings.