Programmable Output 4 - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

DAAB AUTOMATIC CONTROL UNIT EP104

Programmable output 4

No.
Name
o400
Function of output 4
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o410 – o422
2
Presence sensor/Direction sensing. Signal as configured in o491
3
Lock
4
Alarm output Signal as configured in o430 – o439
o410
Open position
0
Disabled
1
Constant signal
2
Flashing signal
o411
Mid position
0
Disabled
1
Constant signal
2
Flashing signal
o412
Closed position
0
Disabled
1
Constant signal
2
Flashing signal
o413
Movement
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o410, o411 and o412.
5
Flashing signal in the opening movement
6
Flashing signal in the closing movement
7
Flashing signal in the opening and closing movement
o414
Delayed switch-off Switch off after the specified
time For example to switch off lighting a specified
time after closing
o420
Warning time before start
o421
Warning function in combination with o420
1
Constant signal before park and automatic closing
2
Constant signal before close signal, park and automatic closing
3
Constant signal before all signals
4
Flashing signal before park and automatic closing
5
Flashing signal before close signal, park and automatic closing
6
Flashing signal before all signals
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
0 - 4
0
0 - 2
0
0 - 2
1
0 - 2
1
0 - 7
0
0.00-9.59 minutes
0.00
0.00-9.59 minutes
0.00
1 - 6
1