Interlock Block; Service Channels - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

DAAB AUTOMATIC CONTROL UNIT EP104

Interlock block

No.
Name
C664
Block of another door
0
No block
1
Opening blocked until the other door is closed
2
Opening blocked until the other door is open
3
Closing blocked until the other door is closed
C665
When blocked, open memory, cancel block with
stop
0
Does not remember open and stop, does not cancel block
1
Remembers open and stop, does not cancel block
2
Does not remember open and stop, cancels block
3
Remembers open and stop, cancels block
C695
Network number for communication
0
Disabled
1
Automatic control unit no. 1 in communication
2
Automatic control unit no. 2 in communication

Service channels

No.
Name
C900
Service channel, for service personnel only Random
number
C901
Service channel, for service personnel only
C902
Service channel, for service personnel only,
checksum
C903
Error code list showing the most recent error
messages.
000 Start of the list, followed by the first error message
...
Error messages
999 End of the list, after the last error message
C999
Show only channels that differ from factory set
values
0
Disabled
1
Shows only channels that differ from factory settings, use + and - to step up or down. The button to
the far left is used for rapid advance, which has no function in this mode.
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
0 – 3
0
0 – 3
3
0 – 2
0
Range
Factory Setting Ref.
000-999
00-99
0000-FFFF
0
page
page
47

Advertisement

Table of Contents
loading

Related Products for DAAB EP104

Table of Contents