Automatic Closing - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

Automatic closing

No.
Name
C500
Automatic closing time
C501
Short automatic closing time
C510
Time for LOOP1, LOOP2 and PHOTO closing
during passage
C520
Blocking time for automatic closing after the stop
button is pressed
C591
Direction sensing for internal closing pulse
00
Disabled
01
Presence detection, signal when LOOP1 is activated, remains until LOOP1 is clear.
02
Presence detection, signal when LOOP2 is activated, remains until LOOP2 is clear.
03
Presence detection, signal when both LOOP1 and LOOP2 are activated, remains until either LOOP1
or LOOP2 are clear.
04
Presence detection, signal when PHOTO is activated, remains until PHOTO is clear.
05
Presence detection, signal when both PHOTO and LOOP1 are activated, remains until either
PHOTO or LOOP1 are clear.
06
Presence detection, signal when both PHOTO and LOOP2 are activated, remains until either
PHOTO or LOOP2 are clear.
07
Presence detection, signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 are clear.
08
Presence detection, signal when either LOOP1 or LOOP2 is activated, remains until either LOOP1 or
LOOP2 are clear.
09
Presence detection, signal when first LOOP1 and then LOOP2 are activated, remains until LOOP2 is
clear.
10
Presence detection, signal when first LOOP1 and then PHOTO are activated, remains until PHOTO
is clear.
11
Presence detection, signal when first LOOP2 and then LOOP1 are activated, remains until LOOP1 is
clear.
12
Presence detection, signal when first LOOP2 and then PHOTO are activated, remains until PHOTO
is clear.
13
Presence detection, signal when first PHOTO and then LOOP1 are activated, remains until LOOP1 is
clear.
14
Presence detection, signal when first PHOTO and then LOOP2 are activated, remains until LOOP2 is
clear.
46
DAAB AUTOMATIC CONTROL UNIT EP104
Range
Factory Setting Ref.
0.00-9.59 minutes
0.00
0.0-9.9 seconds
0.0
0.0-9.9 seconds
0.0
0.00 and 0.20-9.59
0.00
minutes
00 - 14
00