Programmable output 3

No.
Name
o300
Function of output 3
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o310 – o322
2
Presence sensor/Direction sensing. Signal as configured in o391
3
Lock
4
Alarm output Signal as configured in o330 – o339
o310
Open position
0
Disabled
1
Constant signal
o311
Mid position
0
Disabled
1
Constant signal
o312
Closed position
0
Disabled
1
Constant signal
o313
Movement
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o310, o311 and o312.
o314
Delayed switch-off Switch off after the specified
time For example to switch off lighting a specified
time after closing
o320
Warning time before start
o321
Warning function in combination with o320
1
Constant signal before park and automatic closing
2
Constant signal before close signal, park and automatic closing
3
Constant signal before all signals
o322
Function during warning time
1
Output signal deactivated during warning
2
Signal as configured in o310-o313
o330*
Alarm if there is an error as configured in
o331-o339. The alarm is activated for at least the
time set in this channel.
o331*
Alarm for faulty safety edge. Time as in o330.
0
Disabled
1
Constant signal
o332*
Alarm for error message in display
0
Disabled
1
Constant signal
* = Only when o300 is set to 4.
60
DAAB AUTOMATIC CONTROL UNIT EP104
Range
Factory Setting Ref.
0 - 4
1
0 - 1
1
0 - 1
0
0 - 1
0
0 - 4
4
0.00-9.59 minutes
0.00
0.00-9.59 minutes
0.00
1 - 3
1
1 - 2
1
0.00-9.59 minutes
0.00
0 - 1
0
0 - 1
0
Bruksanvisning utgåva 1 för Programversion 4.06