DAAB EP104 Instruction Manual page 65

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

DAAB AUTOMATIC CONTROL UNIT EP104
No.
Name
o491
Function when LOOP2, LOOP2 or PHOTO
activated
01
Presence detection Signal when LOOP1 is activated, remains until LOOP1 is clear.
02
Presence detection Signal when LOOP2 is activated, remains until LOOP2 is clear.
03
Presence detection Signal when both LOOP1 and LOOP2 are activated, remains until either LOOP1
or LOOP2 is clear.
04
Presence detection Signal when PHOTO is activated, remains until PHOTO is clear.
05
Presence detection Signal when PHOTO and LOOP1 are activated, remains until either PHOTO or
LOOP1 is clear.
06
Presence detection Signal when PHOTO and LOOP2 are activated, remains until either PHOTO or
LOOP2 is clear.
07
Presence detection Signal when PHOTO, LOOP1 and LOOP2 are activated, remains until either
PHOTO, LOOP1 or LOOP2 is clear.
08
Presence detection Signal when either LOOP1 or LOOP2 is activated, remains until either LOOP1 or
LOOP2 is clear.
09
Direction sensing Signal when first LOOP1 and then LOOP2 are activated. The signal remains until
LOOP2 is clear.
10
Direction sensing Signal when first LOOP1 and then PHOTO are activated. The signal remains until
PHOTO is clear.
11
Direction sensing Signal when first LOOP2 and then LOOP1 are activated. The signal remains until
LOOP1 is clear.
12
Direction sensing Signal when first LOOP2 and then PHOTO are activated. The signal remains until
PHOTO is clear.
13
Direction sensing Signal when first PHOTO and then LOOP1 are activated. The signal remains until
LOOP1 is clear.
14
Direction sensing Signal when first PHOTO and then LOOP2 are activated. The signal remains until
LOOP2 is clear.
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
01 - 14
01
page
65

Advertisement

Table of Contents
loading

Related Products for DAAB EP104

Table of Contents