DAAB AUTOMATIC CONTROL UNIT EP104

Load guard and motor settings

No.
Name
C200
Load guard function
0
Disabled Service and troubleshooting only
1
Reverse when closing, stop when opening
2
Stop when closing and reverse when opening
3
Reverse when closing and opening
4
Stop when closing and opening
C201 Low current limit active, inactive only with
S
frequency converter (C202 = 4).
0
Inactive
1
Active
C202 Type of power supply
S
0
3x400 V with neutral
1
3x230 V without neutral
2
1x230 V with neutral, asymmetric
3
3x400 V without neutral (see separate instructions)
4
Frequency converter (see separate instructions)
5
1x230 V with neutral, symmetric
C205
Load guard for personal protection active during the
closing movement
0
Disabled
1
Active
C211 Load guard delay
S
C212
Load guard, connection delay on start, all starts
C221
Motor protection delay
C230
Set motor power readout for personal protection,
motor 1
C231
Motor power readout, motor 1
C232
Set load guard limit for motor 1 opening
C233
Set load guard limit for motor 1 closing
C240
Set motor power readout for personal protection,
motor 2
C241
Motor power readout, motor 2
C242
Set load guard limit for motor 2 opening
C243
Set load guard limit for motor 2 closing
C251
Motor current readout, motor 1
C252 Set motor current readout, motor 1 opening
S
C253 Set motor current readout, motor 1 closing
S
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
0 – 4
3
0 – 1
1
0 - 5
0
0-1
1
0.01-2.50 seconds
0.06
0.1-2.5 seconds
1.0
3.0-5.0 seconds
3.0
0.00 and 0.12-0.35
0.20
kW
0.00-1.99 kW
0.05-1.99 kW
0.60
0.05-1.99 kW
0.60
0.00 and 0.12-0.35
0.20
kW
0.00-1.99 kW
0.05-1.99 kW
0.60
0.05-1.99 kW
0.60
0.0-20.0A
0.0 and 0.5-6.0A
1.0
0.0 and 0.5-6.0A
1.0