E961
SE1 did not change to low during the external test.
E962
SE2 did not change to low during the external test.
E963
SE3 did not change to low during the external test.
PHOTO did not change to low during the external
E964
test.
Photocell did not change to low during the external
E965
test.
SE1 did not change to high during the external
E971
test.
SE2 did not change to high during the external
E972
test.
SE3 did not change to high during the external
E973
test.
PHOTO did not change to high during the
E974
external test.
INP6 did not change to high during the external
E975
test.
80
Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C113 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C123 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C133 to 0.
Check that the safety edge is functional, if the safety edge is
not functional, set channel C343 to 0.
Check that the INP6 is working, if no self-test in the INP6,
set channel P643 to 0.