Programmable Input 2 - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

Programmable input 2

No.
Name
P200
Channels in programmable input 2
0
Disabled
1
Enabled
P260
Control function
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
P261
Type of control signal when activated
1
Pulse (hold-to-run mode not possible)
2
Signal for as long as the input is activated
P262
Half operation
1
Motor 1
2
Motor 2
3
Motors 1 and 2
P263
Limited opening
0
Disabled
1
Time opening according to set time in channel C412/C414 or number of degrees in L116/L126 if
encoder is used.
P270
Motor lock
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 2. If the signal disappears the
barrier is stopped.
P275
Opening via input after activation during set time,
input will not open the barrier until it has been
activated for the set time.
P280
Park
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P290
Interlock opening
0
Disabled
1
Opens the local door if P260 is set to open, and passes the signal on to the remote door
P296
Blocking disabled for local and remote doors. Works
only with a constant signal.
0
Disabled
1
Active
P298
Automatic closing disabled for remote door Only
works if there is a constant signal
0
Disabled
1
Active
68
DAAB AUTOMATIC CONTROL UNIT EP104
Range
Factory Setting Ref.
0 - 1
1
0-5
2
1 - 2
1
1 - 3
3
0 - 1
0
0 - 1
0
0.0-9.9 seconds
0.0
0 - 2
2
0 - 1
0
0 - 1
0
0 - 1
0
Bruksanvisning utgåva 1 för Programversion 4.06
page
28