No.
Name
C125*
Set impedance value for safety edge S.E2
Set to 1 only at C121.
C131 Selects function for safety edge S.E3
S
0
S.E3 disabled
1
Limits according to set value in C135
2
Fixed limits between 5 kohm and 15 kohm
C132
Reverse/stop with activated safety edge S.E3
1
Reverse
2
Stop
C133 Check of external protection connected to S.E3
S
0
No check
1
Test of protection connected to S.E3
C134
Impedance readout S.E3
C135
Setting impedance value for safety edge S.E3. Set to
1 only at C131.
40
DAAB AUTOMATIC CONTROL UNIT EP104
Range
Factory Setting Ref.
1.0-9.9 kΩ
8.2
0-2
0
1 – 2
1
0 - 1
1
00.0-99.9 kΩ
1.0-9.9 kΩ
8.2
Bruksanvisning utgåva 1 för Programversion 4.06