Programmable input 6

No.
Name
P600
Channels in programmable input 6
0
Disabled
1
Activated (Only channels P660-P698 activated)
2
Safety input (Only channels P640-P643 activated)
P640
Safety function when input is activated
1
Reverse to fully open
2
Stop with automatic restart of automatic closing
3
Stop, wait for new control signal or time in C520 and thereafter automatic closing.
P641
Safety during run-on time or disengagement angle
in closing movement.
0
Turned off while both leaves is in run past time or shut off angle.
1
Activated according to P640.
P643
Control of external protection connected to INP6
0
No check
1
Test of protection connected to INP6
P660
Control function
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
P661
Type of control signal when activated
1
Pulse
2
Signal for as long as the input is activated
P662
Half operation
1
Motor 1
2
Motor 2
3
Motors 1 and 2
P663
Limited opening
0
Disabled
1
Time opening according to set time in channel C412/C414 or number of degrees in L116/L126 if
encoder is used.
P670
Motor lock
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 6. If the signal disappears the
barrier is stopped.
P675
Opening via input after activation during set time,
input will not open the barrier until it has been
activated for the set time.
72
DAAB AUTOMATIC CONTROL UNIT EP104
Range
Factory Setting Ref.
0 - 1
1
1 – 3
1
0 - 1
0
0 - 1
1
0-5
0
1 - 2
1
1 - 3
3
0 - 1
0
0 - 1
0
0.0-9.9 seconds
0.0
Bruksanvisning utgåva 1 för Programversion 4.06
page
28