• Programmable wireless inputs, r channels

You can use the DB403 add-in card to access four programmable wireless inputs in the EP104.
The instructions are identical for all four wireless inputs, apart from the channel number – input 1 has channel number r1nn,
input 2 has channel number r2nn, etc. The settings below are for output 1.
Use channel r001 for a readout showing which wireless channel is receiving a signal – the value displayed indicates the wireless
input that is in use.

Control functions using wireless inputs

Use the following r channels to select the wireless signal function.
r160 Control function
Change the value in the channel to give the input the desired function. The value 1 means open, 2 means close, etc. See the
channel reference for all possible options.
r162 Half operation
Use this channel to specify whether you want motors 1, 2 or both to operate when the input is activated. 1 = motor 1, 2 =
motor 2 and 3 = both motors 1 and 2.
r163 Limited opening
To specify limited opening, set this channel to 1. The door will then open as configured in C412 and C414.
r170 Block wireless input from a programmable input
This channel is used to disable wireless operation from a programmable input. Make sure that the programmable input is
active and that all the options for the input have been disabled. The value 1 will disable the wireless input if there is no signal
at programmable input 1. Set the correct value for the programmable input you want to use.
r180 Park
Use this setting to allow the wireless input to park the door. If the input is activated, the door opens, but before it can close
a new control signal is required at another input – regardless of the setting for automatic closing.
r190 Interlock opening
In an interlocking system, this input is used to send a command for the local door to open, and to pass on the open
command to the remote door.
'