DAAB AUTOMATIC CONTROL UNIT EP104

Operation

• General

Anyone installing or modifying the EP104 must have a documented familiarity with, and understanding of its functions, as
well as experience of setting up the control system for the application in which it will be used.
Take care when operating internal buttons to avoid touching live components.
The unit may only be connected by a qualified electrician, who accepts responsibility for ensuring that the electric connections
have been carried out in accordance with the applicable standards and this instruction manual.
Anyone commissioning the EP104 must have documented familiarity with, and understanding of its functions, as well as
experience of commissioning control systems for the application to be used.

• Service and maintenance

Regular inspection is required of the external safety features of the EP104, such as safety edges, stop buttons, photocells, load
guards and safety loops. The condition of the enclosure, cables and installation must also be checked. This inspection must be
carried out at least twice a year.
Whenever work is carried out in or near the control unit, the power supply to the EP104 must be disconnected with a locked
main switch.

• Resetting/replacing tripped fuses

If the fuse protecting the power supply to the automatic control unit trips, FAAC Nordic AB recommends following these
steps to reset/replace it.
• Switch off the main switch to the automatic control unit.
• Decouple the motor winder.
• Reset or replace the fuse.
• Switch on the main switch to the automatic control unit.
• Check that none of the motor winders start before receiving the control signal.
• Check that the motor winders can be started and stopped from the control buttons.
• If the motor winder cannot be stopped, contact FAAC Nordic AB.
Bruksanvisning utgåva 1 för Programversion 4.06
189.2
163.8
Earth Terminal
12.7
Ø 4.5 (4x)
Metal screw M4
Control board
Metal spacer, at least 10mm
2 metal washers
Mounting plate
with M4-winding
12.7
9