Programmable Output 2 - DAAB EP104 Instruction Manual

Automatic control unit
Hide thumbs Also See for EP104:
Table of Contents

Advertisement

DAAB AUTOMATIC CONTROL UNIT EP104

Programmable output 2

No.
Name
o200
Function of output 2
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o210 – o222
2
Presence sensor/Direction sensing. Signal as configured in o291
3
Lock
4
Alarm output Signal as configured in o230 – o239
o210
Open position
0
Disabled
1
Constant signal
o211
Mid position
0
Disabled
1
Constant signal
o212
Closed position
0
Disabled
1
Constant signal
o213
Movement
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o210, o211 and o212.
o214
Delayed switch-off Switch off after the specified
time For example to switch off lighting a specified
time after closing
o220
Warning time before start
o221
Warning function in combination with o220
1
Constant signal before park and automatic closing
2
Constant signal before close signal, park and automatic closing
3
Constant signal before all signals
o222
Function during warning time
1
Output signal deactivated during warning
2
Output signal as configured in o210-o213
o230*
Alarm if there is an error as configured in
o231-o239. The alarm is activated for at least the
time set in this channel.
o231*
Alarm for faulty safety edge. Time as in o230.
0
Constant signal
1
Active
o232*
Alarm for error message in display
0
Constant signal
1
Active
* = Only when o200 is set to 4.
Bruksanvisning utgåva 1 för Programversion 4.06
Range
Factory Setting Ref.
0 - 4
1
0 - 1
0
0 - 1
0
0 - 1
1
0 - 4
4
0.00-9.59 minutes
0.00
0.00-9.59 minutes
0.00
1 - 3
1
1 - 2
1
0.00-9.59 minutes
0.00
0 - 1
0
0 - 1
0
page
57