Technical specification

Dimensions (WxHxD)
Power supply
Power supply
Permitted voltage variation
Frequency
Motor in 3-phase operation
3x400 V
Motor in 3-phase operation
3x230 V
Motor
in
single-phase
operation
Fuses
Power consumption
Operating mode
Temperature range
Safety edge
Safety circuit
Internal motor protection
Load guard
Digital inputs
Supply voltage for photocell 24 VDC max. 50 mA.
External supply
Communication
Protection class
10
190x224x60 mm.
3-phase or single-phase.
3x400V+N+PE, 3x230V+PE, 1x230V+N+PE, 3x400V+PE (requires an external
transformer)
±10%
50 Hz.
3-phase asynchronous motor 0.18-1.5 kW.
3-phase asynchronous motor 0.18-0.75kW.
Single-phase motor with capacitor 0.18-0.37 kW.
External fuse max. T10A.
Automatic control unit 22 VA + electric motors.
Intermittent operation 50% / maximum period of operation 4 minutes
0 to 45 °C.
2 closing inputs SE.C1 and SE.C2 for a safety edge while closing.
2 opening inputs SE.O1 and SE.O2 for a safety edge while opening.
Variable impedance 1.0-9.9 kΩ, power capability at least ½ W.
Max. impedance 3 Ω in the stop circuit.
Cable length 0.75 mm2 max. 60 m. Cable length 1.5 mm2 max. 120 m.
One 0-50 V analogue input to measure the voltage after the stop circuit.
Setting range 0.5-6 A.
Setting range 0.05-1.99 kW.
9
Logical 0 0-8 VDC.
Logical 1 12-30 VDC.
Input current 5 mA at 24 VDC.
Cable length max. 200 m
Unregulated 24VDC, 18-28VDC, max 300mA
RS-485 between 2x EP104. Cable length max. 1000m.
The PCB is designed for an enclosure rating of at least IP54.
INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
Instruction manual edition 1 for EP104 version 4.08

Advertisement