Configuration and Connections
4.6 Output Circuits
There are two output signals: Brake interlock and servo alarm. They use non-contract transistor cir-
cuits. The voltage and current specifications for these signals are as follows:
Output circuits require 24 V power supply by the user. We recommend the same 24 V power supply
as that used for the input circuits.
24 V
Flywheel diode (Make
sure the diode is facing
the right direction.)
Applied Voltage (V max.) 3 0 V
Conduction Current (/p) 5 0 mA
SERVOPACK
I,
Output relay
Transistor
Figure 4.6 O u t p u t Circuits
4 -18
Optocoupler
.....1 • Brake interlock
• Servo alarm