■ Specifications
• Lead Wire Length: 500 mm (19.69 in) each
• Max. Ambient Temperature: 60°C
• Lead Wires: Color coded
AC Input
100 V
Blue, White
The following diagrams show the internal circuits. While it is possible to switch either the AC or DC
side of the brake power supply, it is normally safer to switch the AC side. I f the DC side is to be
switched, install a surge suppressor near the brake coil to prevent the surge voltages due to switching
the DC side from damaging the brake coil.
• Internal Circuit for 200-VAC Input (LPSE-2H01)
Diode
Yellow
Surge Suppressor
AC Side
White
• Internal Circuit for 100-VAC Input (LPDE-1H01)
Blue
AC Side
White
200 V
Yellow, White
Red, Black
Red
Surge
Suppressor
DC (Brake) Side
Diode
Black
Red
DC (Brake) Side
Black
9.6 Peripheral Devices
Brake
9