Model Configuration - Hitachi SJ700 Series Manual

Variable frequency drive
Hide thumbs Also See for SJ700 Series:
Table of Contents

Advertisement

STANDARD SPECIFICATIONS
L700 Series
3-phase 200V class
Model L700-
Enclosure (*1)
Applicable motor (4-pole, kW(HP)) (*2)
Rated capacity
(kVA)
Output Ratings
Rated output current (A)
Overload capacity(output current)
Rated output voltage (*3)
Rated input voltage (V)
Input Rating
Rated input current (A)
Dynamic braking (Short-time) (*4)
Braking
Minimum value of resistor (Ω)
Vibration (*5)
EMC filter
Zero-phase Reactor
Weight 〔 kg〕 ( 〔 lbs.〕 )
3-phase 400V class
Model L700-
Enclosure (*1)
Applicable motor (4-pole, kW(HP)) (*2)
Rated capacity
(kVA)
Output Ratings
Rated output current (A)
Overload capacity(output current)
Rated output voltage (*3)
Rated input voltage (V)
Input Rating
Rated input current (A)
Dynamic braking (Short-time) (*4)
Braking
Minimum value of resistor (Ω)
Vibration (*5)
EMC filter
Zero-phase Reactor
Weight 〔 kg〕 ( 〔 lbs.〕 )
*1: The protection method conforms to JIS C 0920(IEC60529).
*2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole).To use other motors, be sure to prevent the rated motor current (50Hz) from exceeding the rated output current of the inverter.
*3: The output voltage decreases as the main power supply voltage decreases except for the use of AVR function.
*4: Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large braking torque is required.
*5: Conforms to the test method specified in JIS C 60068-2-6 : 2010 (IEC 60068-2-6 : 2007).
*6: To operate the motor beyond 50/60Hz, please consult with the motor manufacturer about the maximum allowable rotation speed.
*7: Storage temperature refers to the temperature in transportation.
*8: The frequency command is the maximum frequency at 9.8V for input voltage 0 to 10VDC, or at 19.6mA for input current 4 to 20mA.If this characteristic is not satisfactory for your application,contact your Hitachi representative.
Model Name Indication

Model Configuration

Applicable Motor kW (HP)
LFUF2
3-phase 200V
LFF2
SJ700
HFEF2
3-phase 400V
HFUF2
HFF2
3-phase 200V
LFF
L700
3-phase 400V
HFF
110LFF
150LFF
185LFF
11(15)
15(20)
18.5(25)
200V
15.2
20.0
25.2
240V
18.2
24.1
30.3
44
58
73
3-phase (3-wire) 200 to 240V (corresponding to input voltage)
3-phase 200 to 240V+10%, -15%, 50/60Hz±5%
48
64
80
Built-in BRD circuit (optional resistor)
10
10
7.5
5.9m/s
2
(0.6G), 10-55Hz
6(13.2)
6(13.2)
14(30.8)
110HFF
150HFF
185HFF
11(15)
15(20)
18.5(25)
400V
15.2
20.0
25.6
480V
18.2
24.1
30.7
22
29
37
24
32
41
Built-in BRD circuit (optional resistor)
35
35
24
5.9m/s
2
(0.6G), 10-55Hz
6(13.2)
6(13.2)
14(30.8)
SJ700 - 055 H F E F 2
SJ700 series
Series Name
Applicable Motor Capacity
004: 0.4kW(1/2HP)
|
4000:400kW(500HP)
Power Source
L: 3-phase 200V class
H: 3-phase 400V class
F: With keypad
U
: US version
E
: European version
Note: Japanese version
F: Integrated EMC filter
Version
Available
0.4
0.75
1.5
2.2
3.7
4.0
5.5
(1/2)
(1)
(2)
(3)
(5)
(5)
(7.5)
220LFF
300LFF
370LFF
450LFF
IP20
22(30)
30(40)
37(50)
45(60)
29.4
39.1
48.4
58.5
35.3
46.9
58.1
70.2
85
113
140
169
120%,60sec
94
120
150
186
External dynamic braking unit (option)
7.5
5
2.9m/s
2
(0.3G), 10-55Hz
Built-in (EN61800-3 category C3)
Built-in
14(30.8)
14(30.8)
22(48.4)
30(66)
220HFF
300HFF
370HFF
450HFF
IP20
22(30)
30(40)
37(50)
45(60)
29.7
39.4
58.8
48.4
35.7
47.3
58.1
70.6
43
57
70
85
120%,60sec
3-phase (3-wire) 380 to 480V (corresponding to input voltage)
3-phase 380 to 480V +10%, -15%, 50/60Hz±5%
47
94
63
77
24
20
Built-in (EN61800-3 category C3)
Built-in
14(30.8)
14(30.8)
22(48.4)
30(66)
L700 series
Series Name
Applicable Motor Capacity
7.5
11
15
18.5
22
30
37
45
(7.5)
(15)
(20)
(25)
(30)
(40)
(50)
(60)
550LFF
750LFF
55(75)
75(100)
72.7
93.5
87.2
112.2
210
270
240
280
-
30(66)
43(94.6)
550HFF
750HFF
900HFF
1100HFF
IP00
55(75)
75(100)
90(125)
110(150)
72.7
93.5
110.8
135.0
87.2
112.2
133.0
162.1
105
135
160
195
116
149
176
199
External dynamic braking unit (option)
-
2.9m/s
2
(0.3G), 10-55Hz
30(66)
30(66)
55(121)
55(121)
L700 - 110 L F F
110: 11kW(15HP)
|
1600:160kW(220HP)
Power Source
L: 3-phase 200V class
H: 3-phase 400V class
F: With keypad
F: Integrated EMC filter
55
75
90
110
132
150
160
185
(75)
(100)
(125)
(150)
(175)
(200)
(220)
(250)
1320HFF
1600HFF
132(150)
160(220)
159.3
200.9
191.2
241.1
230
290
253
300
70(154)
70(154)
220
315
400
(300)
(400)
(550)
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

L700 series

Table of Contents