Select The Keypad For Run Command - Hitachi X200 Series Instruction Manual

X200 series inverter
Hide thumbs Also See for X200 Series:
Table of Contents

Advertisement

2 30
2 30
If the Potentiometer Enable LED is OFF, follow these steps below.
(Starting point)
Press the
Press the
Press the
Press the
Select the Keypad for RUN Command – To RUN
command causes the inverter to accelerate the motor
to the selected speed. The Run command can arrive
from various sources, including the control terminals,
the Run key on the keypad or the network. In the
figure to the right, notice the Run Key Enable LED,
just above the Run key. If the LED is ON, the Run
key is already selected as the source, and you may
skip this step. Note that the default setting depends
on the country.
If the Potentiometer Enable LED is OFF, follow these steps below (the table resumes
action from the end of the previous table).
(Starting point)
Press the
Press the
Press the
Press the
NOTE: After completing the steps above, the Run Key Enable LED will be ON. This
does not mean the motor is trying to run; it means that the RUN key is now enabled.
DO NOT press the RUN key at this time – complete the parameter setup first.
Action
FUNC
key.
FUNC
key again.
key.
2
STR
key.
Action
key once.
1
FUNC
key.
key.
1
STR
key.
Display
Func./Parameter
A- - -
"A" Group selected
A001
Speed command source setting
00 = Keypad potentiometer
01 = Control terminals
01
02 = Function F001 setting
03 = ModBus network
04 = Calculate function output
00
00 = Potentiometer (selected)
Store parameter, returns to "A"
A001
Group list
Run Key Enable LED
RUN
FUNC
Display
Func./Parameter
A001
Speed command source setting
A002
Run command source setting
01 = Control terminals
01
02 = Run key on keypad
03 = ModBus network
02
02 = Run key on keypad (selected)
Store parameter, returns to "A"
A002
Group list
POWER
Hz
ALARM
A
RUN
STOP
RESET
PRG
STR
2
1