Distance Between Interpolation Points (P-Comp-00009); Distance Between The Interpolation Points Of The First Master Axis (P-Comp-00032); Distance Between Interpolation Points On The Second Master Axis (P-Comp-00033) - Beckhoff TF5200 Manual

Axis compensation
Hide thumbs Also See for TF5200:
Table of Contents

Advertisement

Data type
STRING
Data range
QUADRATIC: The identical interpolation point distance interval (P-COMP-00009)
[} 19] is used for the two master axes.
RECTANGULAR: Different interpolation point distances interval1 (P-COMP-00032)
[} 19] and interval2 (P-COMP-00033) [} 19] can be set for the two master axes.
Axis types
T, R, S
Dimension
T: ----
Default value
QUADRATIC
Remarks
3.2.3

Distance between interpolation points (P-COMP-00009)

P-COMP-00009
Distance between interpolation points
Description
This parameter defines the distance between two interpolation points if both axes
use an identical grid (P-COMP-000031 [} 18](grid) = QUADRATIC).
Parameter
kw.crosscomp2.interval
Data type
UNS32
Data range
0 < interval < MAX(UNS32)
Axis types
T, R, S
Dimension
T: 0.1 µm or increments
Default value
0
Remarks
3.2.4
Distance between the interpolation points of the first master
axis (P-COMP-00032)
P-COMP-00032
Distance between the interpolation points of the first master axis
Description
The parameter defines the interval between two interpolation points for the first
master axis if both master axes use a different grid (P-COMP-00031 [} 18](grid) =
RECTANGULAR).
Parameter
kw.crosscomp2.interval1
Data type
UNS32
Data range
0 < interval1 < MAX(UNS32)
Axis types
T, R, S
Dimension
T: 0.1 µm or increments
Default value
0
Remarks
3.2.5
Distance between interpolation points on the second master
axis (P-COMP-00033)
P-COMP-00033
Distance between the interpolation points on the second master axis
Description
The parameter defines the interval between two interpolation points for the first
master axis if both master axes use a different grid (P-COMP-00031 [} 18](grid) =
RECTANGULAR).
Parameter
kw.crosscomp2.interval2
Data type
UNS32
Data range
0 < interval2 < MAX(UNS32)
Axis types
T, R, S
TF5200 | TwinCAT 3 CNC
Axis compensation
General compensation value data (kw.*)
R,S: ----
R,S: 0.0001° or increments
R,S: 0.0001° or increments
Version: 1.22
19