9.4
Display and control elements 24 V DC
Status LED yellow
Figure 24:
Description LED and Jumpers - 24 V DC
NOTE!
Breakage of the pneumatic connection pieces due to rotational impact.
▶ When unscrewing and screwing in the transparent cap, do not hold the actuator of the process valve but the
connection housing.
Figure 25:
Open control head
NOTE!
Damage or malfunction due to penetration of dirt and humidity.
▶ To observe degree of protection IP65 / IP67, screw the transparent cap in all the way.
9.4.1
Status LED yellow
LED yellow
flashing
Teach function is running
Puck not available
flickers
→
Table 4:
Status LED yellow - 24 V DC
9.4.2
Valve LED yellow
The yellow LED (valve) indicates whether the pilot valve is actuated (LED is lit yellow).
36
Insert puck
english
End position LED green
Jumper for
assignment of
end position LEDs
End position LED yellow
Valve LED yellow (pilot valve)
Transparent cap
Body casing
Connection housing
Actuator
Type 8695