Using the jumpers, assign the required color to the end position LEDs.
Figure 27:
Description end position LEDs and Jumper - 24 V DC
NOTE!
Breakage of the pneumatic connection pieces due to rotational impact.
▶ When unscrewing and screwing in the transparent cap, do not hold the actuator of the process valve but the
connection housing.
Damage or malfunction due to penetration of dirt and humidity.
▶ To observe degree of protection IP65 / IP67, screw the transparent cap in all the way.
Close the device (assembly tool: 674078
Figure 28:
Close control head
The assembly tool (674078) is available from your Bürkert sales office.
5)
38
End position LED green
Jumper for
assignment of end
position LEDs
End position LED yellow
).
5)
english
Top
Bot
ye
ye
gn
gn
Bot
Top
Top
Bot
ye
ye
gn
gn
Bot
Top
Transparent cap
Body casing
Connection housing
Actuator
Type 8695
Electrical installation 24 V DC
Jumper setting 1:
In the end position top (Top),
the yellow LED is lit; in the
end position bottom (Bot),
the green LED is lit.
Jumper setting 2:
In the end position top (Top),
the green LED is lit; in the
end position bottom (Bot),
the yellow LED is lit.