ADEMCO Via 30+ Installation Instructions Manual page 43

Hide thumbs Also See for Via 30+:
Table of Contents

Advertisement

5816
Door/Window
Transmitter
Has two unique input yoo?) codes: one for a
wired closed circuit contact loop, and the other
for a built-in reed switch (used in conjunction
INPUT
with a magnet).
(LOOP)
5817
Multi-Point
Universal
Transmitter
1
Has three unique input (loop) codes: one for a
(PRIMARY) —_ DIP switch settable "Primary" contact loop, and
the others for two "Auxiliary® closed
circuit
2
contact loops. The "Primary" loop may be set for:
7
(AUX. CENTER)
a) Repeating or Single Transmission, b) Normally
LaF =a
Open or Normally Closed Circuit, c) Slow or Fast
Mines
SISISISISIS)
3
Response, and d) 3 Minute or No Transmission
(AUX. RIGHT)
—[nhibit.
code.
5827
Wireless
Keypad
Can be used to turn the burglary protection on
and off, and features the same built-in panic
6)
functions as wired keypads for either silent or
INPUT
(LOOP)
2
(REED)
(TERMINALS)
audible 24 hour alarm. An LED indication lights
INPUT
each
time
a
key
is pressed,
to
verify
(LOOP)
transmission.The keypad is identified as zone
1
"00" on wired keypads when it transmits with a
LEARN AS "RF"
low battery .
Can
operate
the system
similarly to wired
keypads and can indicate system status via its 3
LEDs and sounder. Includes 3 panic keys for 24
5827
5827BD
hour silent or audible alarm. Requires a 5800TM
Transmitter Module, to operate in conjunction
with
system's
4281/5881
receiver.
Key
rogrammed, has no DIP switch. The keypad is
identified as zone "00" on wired keypads when it
transmits with a low battery.
5849
Glass
Break
Detector/Transmitter
Note:
There is a 3 minute lock-out between fault
transmissions to conserve battery life.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the
user are vital to continuous satisfactory operation of any alarm system.
~43-