ENTER PROGRAMMING MODE | 1.
POWER UP, then depress
[*] and [#] both at once, within
50sec of powering up.
2.
Initially, key:
4+1+1+1
plus CODE
key + 0.
OR
13.
If different Master Code is programmed,
key :
MASTER
CODE
+ CODE
KEY
+ 0.
(if *98 was used to exit previously,
method 1 above must be used to enter
INITIALIZE DOWNLOAD ID
AND
SUBSCRIBER ACCT NUMBER
FOR DOWNLOADING
TO DEFAULT VALUES
EXIT PROGRAMMING MODE
| * 98
Inhibits re-entry to programming
mode via type 2 or 3 entry method
above.
*99
Allows re-entry to programming
mode via
type 2 or 3 entry
method.
[¥] + Field No. (e.g., 21, 38, 56, etc.)
[*] + Field No., followed by data entries.
Some fields require sequential pressings of
*] to enter data (e.g., fields 56, 80, 81).
[*] + Field No. + [*] (only applies to
fields 40 thru 43 and 94).
READ FIELD
[#] + Field No. Data will either be
automatically sequentially displayed or can
be displayed by successivel
i n g
[#].
*96
No data entry required,
loads defaults.